Source: FDA, National Drug Code (US) Revision Year: 2020
DaTscan is a radiopharmaceutical indicated for striatal dopamine transporter visualization using single photon emission computed tomography (SPECT) brain imaging to assist in the evaluation of adult patients with suspected Parkinsonian syndromes (PS). In these patients, DaTscan may be used to help differentiate essential tremor from tremor due to PS (idiopathic Parkinson’s disease, multiple system atrophy and progressive supranuclear palsy). DaTscan is an adjunct to other diagnostic evaluations.
DaTscan emits radiation and must be handled with safety measures to minimize radiation exposure to clinical personnel and patients. Radiopharmaceuticals should be used by or under the control of physicians who are qualified by specific training and experienced in the safe use and handling of radionuclides, and whose experience and training have been approved by the appropriate government agency authorized to license the use of radionuclides. DaTscan dosing is based upon the radioactivity determined using a suitably calibrated instrument immediately prior to administration.
To minimize radiation dose to the bladder, encourage hydration prior to and following DaTscan administration in order to permit frequent voiding. Encourage the patient to void frequently for the first 48 hours following DaTscan administration [see Dosage and Administration (2.5)].
Before administration of DaTscan, administer Potassium Iodide Oral Solution or Lugol’s Solution (equivalent to 100 mg iodide) or potassium perchlorate (400 mg) to block uptake of iodine 123 by the patient’s thyroid. Administer the blocking agent at least one hour before the dose of DaTscan [see Warnings and Precautions (5.2)].
The recommended dose is 111 to 185 MBq (3 to 5 mCi) administered intravenously [see Clinical Studies (14)].
The estimated radiation absorbed doses to an average adult from intravenous injection of DaTscan are shown in Table 1. The values are calculated assuming urinary bladder emptying at 4.8-hour intervals and appropriate thyroid blocking (iodine 123 is a known Auger electron emitter).
Table 1. Estimated Radiation Absorbed Doses from DaTscan:
ORGAN / TISSUE | ABSORBED DOSE PER UNIT ADMINISTERED ACTIVITY (µGy / MBq) | |
---|---|---|
Adrenals | 12.9 | |
Brain | 17.8 | |
Striata | 230 | |
Breasts | 7.8 | |
Esophagus | 10 | |
Gallbladder Wall | 26.4 | |
GI Tract | Stomach Wall | 11.2 |
Small Intestine Wall | 21.2 | |
Colon Wall* | 39.8 | |
Upper Large Intestine Wall | 38.1 | |
Lower Large Intestine Wall | 42 | |
Heart Wall | 12.9 | |
Kidneys | 10.9 | |
Liver | 27.9 | |
Lungs | 41.2 | |
Muscle | 9.4 | |
Osteogenic Cells | 28.2 | |
Ovaries | 16.8 | |
Pancreas | 13 | |
Red Marrow | 9.2 | |
Skin | 6 | |
Spleen | 10.4 | |
Testes | 8.5 | |
Thymus | 10 | |
Thyroid | 9 | |
Urinary Bladder Wall | 53.1 | |
Uterus | 16.1 | |
Total Body | 11.3 | |
EFFECTIVE DOSE PER UNIT ADMINISTERED ACTIVITY (µSv/MBq) | 21.3 |
* The absorbed dose to the colon wall is the mass-weighted sum of the absorbed doses to the upper and lower large intestine walls, D = 0.57D + 0.4 3D [Publication 80 of the ICRP (International Commission on Radiological Protection); Annals of the ICRP 28 (3). Oxford: Pergamon Press; 1998]
The Effective Dose resulting from a DaTscan administration with an administered activity of 185 MBq (5 mCi) is 3.94 mSv in an adult.
Begin SPECT imaging 3 to 6 hours following DaTscan administration. Acquire images using a gamma camera fitted with high-resolution collimators and set to a photopeak of 159 keV with a ± 10% energy window. Angular sampling should be not less than 120 views over 360 degrees. Position the subject supine with the head on an off-the-table headrest, a flexible head restraint such as a strip of tape across the chin or forehead may be used to help avoid movement, and set a circular orbit for the detector heads with the radius as small as possible (typically 11 to 15 cm).
Experimental studies with a striatal phantom suggest that optimal images are obtained with matrix size and zoom factors selected to give a pixel size of 3.5 to 4.5 mm. Collect a minimum of 1.5 million counts for optimal images.
DaTscan images are interpreted visually, based upon the appearance of the striata. Reconstructed pixel size should be between 3.5 and 4.5 mm with slices 1 pixel thick. Optimum presentation of the reconstructed images for visual interpretation is transaxial slices parallel to the anterior commissure-posterior commissure (AC-PC) line. Determination of whether an image is normal or abnormal is made by assessing the extent (as indicated by shape) and intensity of the striatal signal. Image interpretation does not involve integration of the striatal image appearance with clinical signs and/or symptoms.
Normal:
In transaxial images, normal images are characterized by two symmetric comma- or crescent-shaped focal regions of activity mirrored about the median plane. Striatal activity is distinct, relative to surrounding brain tissue (Figure 1).
Abnormal:
Abnormal DaTscan images fall into at least one of the following three categories (all are considered abnormal).
The clinical consequence of overdose with DaTscan has not been reported. It is unknown whether or not ioflupane is dialyzable. Due to the small quantity of ioflupane in each vial, overdosage with ioflupane is not expected to result in pharmacologic effects. The major risks of overdose relates predominantly to increased radiation exposure, with the long-term risks for neoplasia. In case of overdosage of radioactivity, frequent urination and defecation should be encouraged to minimize radiation exposure to the patient; care should be taken to avoid contamination from the radioactivity eliminated by the patient.
Store DaTscan at 20° to 25°C (68° to 77°F). This product does not contain a preservative. Store DaTscan within the original lead container or equivalent radiation shielding.
Do not use DaTscan (Ioflupane I 123 Injection) preparations after the expiration date and time stated on the label.
This preparation is approved for use by persons licensed by the Illinois Emergency Management Agency pursuant to 32 IL. Adm. Code Section 330.260(a) and 335.4010 or equivalent licenses of the Nuclear Regulatory Commission or an Agreement State.
© All content on this website, including data entry, data processing, decision support tools, "RxReasoner" logo and graphics, is the intellectual property of RxReasoner and is protected by copyright laws. Unauthorized reproduction or distribution of any part of this content without explicit written permission from RxReasoner is strictly prohibited. Any third-party content used on this site is acknowledged and utilized under fair use principles.