Source: Medicines & Healthcare Products Regulatory Agency (GB) Revision Year: 2014 Publisher: DR GERHARD MANN CHEM-PHARM FABRIK GMBH BRUNSBUTTELER DAMM 165-173 13581 BERLIN GERMANY
To obtain rapid and complete miosis after delivery of the lens in cataract surgery as well as in penetrating keratoplasty, iridectomy and other anterior segment surgery where rapid complete miosis is required.
Miochol-E is for intraocular irrigation only. A freshly prepared 1% solution should be used in the anterior chamber of the eye during surgery.
In most cases a satisfactory miosis, which will last for approximately 20 minutes, is produced in seconds by 0.5-2.0ml. A second application may be made at the discretion of the surgeon if prolonged miosis is required.
Safety and effectiveness in children has not been established.
Intraocular irrigation during surgery.
The symptoms of overdosage are likely to be effects resulting from systemic absorption, ie bradycardia, hypotension, flushing, breathing difficulties and sweating. Atropine sulphate (0.5-1mg) should be given intramuscularly or intravenously and should be readily available to counteract possible overdosage. Adrenaline (0.1-1mg subcutaneously) is also of value in overcoming severe cardiovascular or bronchoconstrictor responses.
Unopened: 24 months.
Opened: Use immediately after reconstitution.
Do not store above 25°C. Do not freeze. Do not resterilise.
Miochol-E is supplied as packs containing 1 blister and 1 filter hub.
Packs are subjected to antimicrobial treatment with ethylene oxide.
One blister contains:
One filter hub with 5 micron filter, luer lock (CE marking number: CE 0123)
The reconstituted preparation is a clear, colourless solution.
Warning: Do not use if blister or peelable backing is damaged or broken. Open under aseptic conditions only. The contents of the blister can be guaranteed as sterile.
Directions for preparing Miochol-E:
The solution must be mixed just before use since aqueous solutions of acetylcholine are unstable. Only clear and colourless solutions should be used.
Miochol-E should not be re-sterilised. The filter hub is recommended only for use with Miochol-E. Aspiration through the filter is not recommended. However, if utilised, discard needle and syringe filter to prevent recontamination of fluids during injection.
Do not aspirate and inject through the same filter.
Do not use unless a clear and colourless solution is produced. For single use only. Discard any unused solution.
© All content on this website, including data entry, data processing, decision support tools, "RxReasoner" logo and graphics, is the intellectual property of RxReasoner and is protected by copyright laws. Unauthorized reproduction or distribution of any part of this content without explicit written permission from RxReasoner is strictly prohibited. Any third-party content used on this site is acknowledged and utilized under fair use principles.