Source: Medicines & Healthcare Products Regulatory Agency (GB) Revision Year: 2020 Publisher: Bio Products Laboratory Limited, Dagger Lane, Elstree, Hertfordshire, WD6 3BX, United Kingdom
Hypersensitivity to the active substance or to any of the excipients listed in section 6.1.
In order to improve traceability of biological medicinal products, the name and the batch number of the administered product should be clearly recorded.
Allergic type hypersensitivity reactions are possible with Optivate. The product contains traces of human proteins other than factor VIII and VWF.
If symptoms of hypersensitivity occur, patients should be advised to discontinue use of the medicinal product immediately and contact their physician. Patients should be informed of the early signs of hypersensitivity reactions including hives, generalised urticaria, tightness of the chest, wheezing, hypotension, and anaphylaxis.
In case of shock, standard medical treatment for shock should be implemented.
The formation of neutralising antibodies (inhibitors) to factor VIII is a known complication in the management of individuals with haemophilia A. These inhibitors are usually IgG immunoglobulins directed against the factor VIII pro-coagulant activity, which are quantified in Bethesda Units (BU) per ml of plasma using the modified assay. The risk of developing inhibitors is correlated to the severity of the disease as well as the exposure to factor VIII, this risk being highest within the first 50 exposure days but continues throughout life although the risk is uncommon.
The clinical relevance of inhibitor development will depend on the titre of the inhibitor, with low titre posing less of a risk of insufficient clinical response than high titre inhibitors.
In general, all patients treated with human coagulation factor VIII products should be carefully monitored for the development of inhibitors by appropriate clinical observations and laboratory tests. If the expected factor VIII activity plasma levels are not attained, or if bleeding is not controlled with an appropriate dose, testing for factor VIII inhibitor presence should be performed. In patients with high levels of inhibitor, factor VIII therapy may not be effective and other therapeutic options should be considered. Management of such patients should be directed by physicians with experience in the care of haemophilia and factor VIII inhibitors.
In patients with existing cardiovascular risk factors, substitution therapy with factor VIII may increase the cardiovascular risk.
If a central venous access device (CVAD) is required, risk of CVAD-related complications including local infections, bacteraemia and catheter site thrombosis should be considered.
Standard measures to prevent infections resulting from the use of medicinal products prepared from human blood or plasma include selection of donors, screening of individual donations and plasma pools for specific markers of infection and the inclusion of effective manufacturing steps for the inactivation/removal of viruses. Despite this, when medicinal products prepared from human blood or plasma are administered, the possibility of transmitting infective agents cannot be totally excluded. This also applies to unknown or emerging viruses and other pathogens.
The measures taken are considered effective for enveloped viruses such as human immunodeficiency virus (HIV), hepatitis B virus (HBV) and hepatitis C virus (HCV), and for the non-enveloped hepatitis A virus. The measures taken may be of limited value against non-enveloped viruses such as parvovirus B19. Parvovirus B19 infection may be serious for pregnant women (fetal infection) and for individuals with immunodeficiency or increased erythropoiesis (e.g. haemolytic anaemia).
Appropriate vaccination (hepatitis A and B) should be considered for patients in regular/repeated receipt of human plasma derived factor VIII products.
It is strongly recommended that every time Optivate is administered to a patient, the name and batch number of the product are recorded in order to maintain a link between the patient and the batch of the product.
The listed warnings and precautions apply both to adults and children.
No interactions of human coagulation factor VIII products with other medicinal products have been reported.
Animal reproduction studies have not been conducted with factor VIII. Based on the rare occurrence of haemophilia A in women, experience regarding the use of factor VIII during pregnancy and breast-feeding is not available. Therefore, factor VIII should be used during pregnancy and lactation only if clearly indicated.
Optivate has no influence on the ability to drive and use machines.
Hypersensitivity or allergic reactions (which may include angioedema, burning and stinging at the infusion site, chills, flushing, generalised urticaria, headache, hives, hypotension, lethargy, nausea, restlessness, tachycardia, tightness of the chest, tingling, vomiting, wheezing) have been observed rarely and may in some cases progress to severe anaphylaxis (including shock).
Development of neutralising antibodies (inhibitors) may occur in patients with haemophilia A treated with factor VIII, including Optivate. If such inhibitors occur, the condition may manifest itself as an insufficient clinical response. In such cases, it is recommended that a specialised haemophilia centre be contacted.
For safety information with respect to transmissible agents, see section 4.4.
The table presented below is according to the MedDRA system organ classification (SOC and Preferred Term Level).
Frequencies have been evaluated according to the following convention: very common (≥1/10); common (≥1/100 to <1/10); uncommon (≥1/1,000 to <1/100); rare (≥1/10,000 to <1/1,000); very rare (<1/10,000), not known (cannot be estimated from the available data). The table lists adverse reactions reported from 96 patients in clinical studies. Approximately 10% of patients can be expected to experience adverse reactions on long-term treatment.
MedDRA Standard System Organ Class | Adverse reactions | Frequency |
---|---|---|
Blood and lymphatic system disorders | Factor VIII inhibition | Uncommon (PTPs)* Very common (PUPs)* |
Nervous system disorders | Headache | Common |
Somnolence | Common | |
Ear and labyrinth disorders | Vertigo | Common |
Skin and subcutaneous tissue disorders | Rash | Common |
Pruritus | Common | |
Musculoskeletal and connective tissue disorders | Musculoskeletal stiffness and joint stiffness | Common |
General disorders and administration site disorders | Infusion site erythema, rash or pain | Common |
Oedema peripheral | Common | |
Chills | Common | |
Pyrexia | Common |
* Frequency is based on studies with all factor VIII products which included patients with severe haemophilia A. PTPs = previously-treated patients, PUPs = previously-untreated patients.
In post-marketing experience, the following additional undesirable effects have been reported: sneezing, cough, throat irritation, abdominal pain and malaise.
Frequency, type and severity of adverse reactions in children are expected to be the same as in adults.
Reporting suspected adverse reactions after authorisation of the medicinal product is important. It allows continued monitoring of the benefit/risk balance of the medicinal product. Healthcare professionals are asked to report any suspected adverse reactions via the Yellow Card Scheme. Website: www.mhra.gov.uk/yellowcard or search for MHRA Yellow Card in the Google Play or Apple App Store.
In the absence of compatibility studies, this medicinal product must not be mixed with other medicinal products.
Only the provided injection/infusion sets should be used because treatment failure can occur as a consequence of human plasma coagulation factor VIII adsorption to the internal surfaces of some infusion equipment.
© All content on this website, including data entry, data processing, decision support tools, "RxReasoner" logo and graphics, is the intellectual property of RxReasoner and is protected by copyright laws. Unauthorized reproduction or distribution of any part of this content without explicit written permission from RxReasoner is strictly prohibited. Any third-party content used on this site is acknowledged and utilized under fair use principles.